What was found
DURING INSPECTION OF THE LH TR NOTED MULTIPLE SPOTS OF CORROSION ON THE INSIDE SIDES OF THE UPPER BUCKET. MECHANICALLY BLENDED 13 EA. AREAS OF CORROSION ON THE LH THRUST REVERSER UPPER DOOR, INBD AND OUTBD AREAS IAW CE680A SRM 51-10-01 AND SRM 51-70-03. AFTER NDT TESTING, DETERMINED BLENDED AREAS TO BE BEYOND LIMITATIONS OF 0.002 INCH OF MATERIAL LOSS FROM NOMINAL THICKNESS IAW CE680A SRM 51-70-03. COMPLIED WITH NETJETS ENGINEERING RFTS-114547 REV.0 TITLE: N506QS (680A-0043) LH UPPER TR DOOR CORROSION DATE: 01AUG25.