Service difficulty report · Floor Panel · Urocop EC135T2

Difficulty date
February 19, 2026
Submitted
February 19, 2026
Operation
Air carrier
Filed by
2A6R933B
Air Methods, LLC
Aircraft
N135LC
Make and model
Urocop EC135T2
Aircraft serial
0296
Aircraft time
9,749 hours, 33,760 cycles
Part
Floor Panel
Part number
L533M1014106
Condition
Dented
Location
Zone 100
Part time
9,749 hours, 33,760 cycles
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DENT DAMAGE MEASURING 13.5” LONG AND 2.5” WIDE WITH A MAXIMUM DEPTH OF 0.065” WAS DISCOVERED ON THE L/H SIDE OF THE COCKPIT FLOOR SKIN NEAR F.S 2,675MM APPROXIMATELY 0.5” FROM THE EDGE OF THE CENTER CONSOLE. THE DAMAGED AREA WAS POTTED WITH EA9309.3NA ADHESIVE AND A .025” 2024-T3 REPAIR DOUBLER WAS FABRICATED AND INSTALLED OVER TOP OF THE REPAIR AREA. A DETAILED DESCRIPTION OF THE DAMAGE AND AN APPROVED REPAIR PROCEDURE IS PROVIDED IN AIR METHODS ENGINEERING AUTHORIZATION 23-5321-EA-5441 REV – . FOR MORE INFORMATION, REFERENCE AIR METHODS (UNITED ROTORCRAFT) WORK ORDER MG750.

More about the Urocop EC135T2