Service difficulty report · Solenoid · Braero HAWKER1000

Difficulty date
May 17, 2015
Submitted
June 18, 2015
Operation
Air carrier
Aircraft
N207K
Make and model
Braero HAWKER1000
Aircraft serial
259045
Engine
Pwc PT6A42A
Engine time
13,178 hours, 7,966 cycles
Part
Solenoid
Part number
31B419704
Part serial
864
Condition
Intermittent
Location
Rt Engine
Part time
12,911 hours, 7,817 cycles
Stage of operation
TX
How discovered
C
Nature of condition
E, A
Precautionary procedure
E, F

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AT 0915 LOCAL TIME THEY WERE POSITIONED ON AIRPORT HOLDING, SHORT OF RUNWAY 19. NOTICED AIR CONDITIONING WAS NOT MAINTAINING & CABIN WAS GETTING WARM. AFTER CLEARANCE WAS GIVEN FOR TAKEOFF, POWER WAS APPLIED & THE ACFT BEGAN TO SHAKE, FELT LIKE A COMPRESSOR STALL. THE POWER WAS INSTANTLY PULLED BACK & THE VIBRATION WENT AWAY, WHEN POWER WAS APPLIED AGAIN IT STARTED TO SHAKE AGAIN. AT THE POINT THE ACFT BEHIND ADVISED THEM THERE WERE FLAMES COMING OUT THE NR 2 ENG. THE PIC CALLED FOR THE ENG FIRE CHECKLIST & PULLED THE T HANDLE. THE CREW INITIALLY FIRED THE NR 2 BOTTLE, 1ST SHOOT BUT DID NOT GET AN INDICATION THAT IT HAD GONE OFF. TAXIED ACROSS THE RUNWAY & WENT INTO THE HOLD AREA, RAN THE CHECKLIST AGAIN DURING WHICH WE HAD AN ORAL FIRE WARNING HORN & BLEW THE NR 2 ENG FIRE BOTTLE 2ND SHOOT AT THAT TIME. THE SECOND SHOOT DID GIVE THEM NOTIFICATION THAT IT HAD FIRED. CALLED FOR THE FIRE TRUCKS & THEY SHOWED UP, DID A VISUAL INSPECTION & GAVE THEM THE GREEN LIGHT TO RETURN TO THE GATE. THEY HAD THE FIRE & RESCUE FOLLOW FOR PRECAUTIONARY REASONS DUE TO PAX ON BOARD. WHEN THE VIBRATION HAPPENED PIC’S FIRST INDICATION ON THE ANNUNCIATOR PANEL WAS A FADAC 2 MALFUNCTION, FOLLOWED BY THE REMAINDER LIGHTS AFTER SHUTTING DOWN AN ENG. AGAIN THE LIGHT THAT THE PIC SAW WAS A FADAC 2 MALFUNCTION LIGHT. WHEN THE ENG WAS COMPRESSOR STALLING MY GAUGES FOR ITT & N2 WERE VERY ERRATIC. ACFT TAXIED TO THE GATE WITH NR 1 ENG LEAVING NR 2 ENG SHUTDOWN. AFTER RETURNING TO THE GATE & UNLOADING THE PAX, THE ACFT WAS VISUALLY INSPECTED. NOTICED SOME BLACK SOOT UNDERNEATH THE ENG FROM THE EVENTS & A STRONG ODOR OF ELEC BURNING. INSPECTED THE NR 2 ENG & FOUND THE OIL LEVEL GOOD & OIL LOOKED CLEAN. ENG GEN SHOWED NO DEFECTS & WOULD ROTATE BY HAND. WHEN ENG WAS ROTATED BY HAND WHEN COOL MX NOTICED CLUNKS & GRINDING AS THE ENG ROTATED. REPRESENTATIVE ON THE SCENE ELECTED TO REMOVE MOTOR & SEND IN FOR TEARDOWN. AWAITING TEARDOWN REPORT OF CAUSE.