What was found
LOST BOTH PACKS AT 33,000 FT, COULD NOT RECOVER PACKS. PERFORMED ADJUSTMENT TEST RT TEMP CONTROL SYS, FOUND NORMAL ON GROUND IAW MM 21-60-00. PERFORMED ADJUSTMENT TEST LT TEMP CONTROL FOUND PACK IN AUTO INOPERATIVE. PERFORMED LT & RT PACK TEMPERATURE CONTROL INTEGRITY CHECK A AND OPS CHECK IAW BILL OF WORK 2655, AND MM 21-60-00, OPS CHECKED PASSED.