What was found
WHEN GEAR DOWN SELECTED, HYD CASS, PULLED QRH THEN CASS WENT AWAY AND GEAR CAME DOWN. A POOR CONNECTION AT PIN "P" OF TB 1611-02, WIRE T1076B22 WAS FOUND TO BE AT FAULT. RELOCATED WIRES T1076B22, T1076A22 AND T1075B22 TO PINS F, M, AND X OF TB1611-02. PERFORMED 5 SUCCESSFUL, CONSECUTIVE GEAR SWINGS WITH NO DEFECTS NOTED IAW AMM 12-B-32-30-00-00A-903A-A.