What was found
WHILE WORKING KEEL BEAM NR0389, FOUND CORROSION ON THE SHEAR TIE AT BS 1070 BETWEEN STR 29 AND STR 28L AFTER REMOVING SEAL FOR ACCESS OF AREA. CORROSION FOUND TO BE OUT OF LIMITS, REMOVED SHEAR TIE, FABRICATED SHEAR TIE, DOUBLER, AND FILLER, ALODINED, PRIMED AND PAINTED AS REQ, SEALED PARTS, REPAIRED SHEAR TIE PER FEDEX SRM 53-10-4.