As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING D-CHECK, AFT CARGO AREA OF SURFACE CORROSION IN STR 29R CHANNEL AND ON STR SPLICE APPROX 6 INCHES AFT OF FS 1010 FRAME. REMOVED FASTENERS AND FABRICATED SPLICE PLATE. REPLACED SPLICE AS PER SRM 51-10-1 PAR 4. INSTALLED FASTENERS PER SRM 51-30-2. TOTAL CYCLES 29577.