What was found
DURING PHASE INSPECTION IN MSP, FOUND SMALL CRACK IN RT INBOARD NACELLE FORMER P/N 27-35025-968. THE REPAIRS WERE COMPLETED BY REPLACING THE FORMER, P/N 27-35025-968 AND SKIN PANEL, P/N 27-35001-180, IAW FAC SRM 51-00-00 PAGE 4, 51-40-00, 51-30-00 AND 54-90-10. (W)