SDR 95ZZZX4006

Service difficulty report · Relay · Mooney M20J

Difficulty date
June 22, 1995
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N205PP
Make and model
Mooney M20J
Aircraft serial
243061
Part
Relay
Condition
Trip Breaker
Location
Flap Motor
Part time
495 hours
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

A.C. INTERMITTENT TRIP 5 AMP CIRCUIT BREAKER WHEN FLAP HANDLE MOVED TO TAKEOFF POSITION OR FULL FLAPS. THEN, WHEN POWER WAS TURNED ON, CIRCUIT BREAKER WOULD POP. MOONEY HAS A NEW FLAP RELAY REPLACEMENT, PN 800376-503. VERY HARD TO TROUBLESHOOT BECAUSE THIS SERIES IS ONLY A/C THAT HAS PRE-SELECTED FLAP POSITIONS PUT TO TAKEOFF, AND FLAPS WILL MOVE TO POSITION AND STOP WITHOUT PILOT HELP.