What was found
TA-7 FUEL CONTROL, TIP SEAL PUMP EQUIPPED, WAS FOUND TO HAVE WORN SPLINES. PUMP SECONDARY FUEL FLOW REDUCED TO ZERO PPH. PRIMARY PUMP FLOW REMAINED FULLY FUNCTIONAL. DRIVE SHAFT AND MATING PUMP GEAR SET WERE REPLACED WHILE CONTROL WAS RETURNED REPAIRED.