SDR 9610909943

Service difficulty report · Temp Sensor · Doug DC931

Difficulty date
May 17, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N1308T
Make and model
Doug DC931
Aircraft serial
47315
Part
Temp Sensor
Condition
Malfunctioned
Location
Tail Compt
Stage of operation
CL
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED DURING CLIMB-OUT. FLIGHT RETURNED TO DFW AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE RIGHT TEMPERATURE SENSOR. LEAK CHECK WAS PERFORMED ON ALL PNEUMATIC DUCTING IN THE TAIL COMPARTMENT. NO LEAKS WERE FOUND. AIRCRAFT RETURNED TO SERVICE.