What was found
DURING CLIMBOUT WHILE RETRACTING THE LANDING GEAR, THE NOSE LANDING GEAR WOULD NOT RETRACT. CYCLED LANDING GEAR HANDLE AND ALL INDICATIONS WERE NORMAL. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED NOSE LANDING GEAR PROXIMITY SENSORS 24GA AND 25GA, OPERATIONAL CHECK OK.