What was found
CABIN CORROSION ON FLOOR WEB STA 1178 APPROX 55 INCHES LBL UPPER SURFACE UNDER CHORD ANGLE. CUT OUT DAMAGED FLOOR WEB AREA, FABRICATED AND INSTALLED DOUBLER REPAIR PER SRM 51-40-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN CORROSION ON FLOOR WEB STA 1178 APPROX 55 INCHES LBL UPPER SURFACE UNDER CHORD ANGLE. CUT OUT DAMAGED FLOOR WEB AREA, FABRICATED AND INSTALLED DOUBLER REPAIR PER SRM 51-40-2.