NR6024, RT WING NR 1 SLAT O/B RIB FRAME BORESCOPE INSP HAS A CRACK INDICATION APPRX .3125 INCH PASSING THROUGH NUTPLATE AS VIEWED THROUGH LWR ACCESS HOLE. *S/D* INSTALLED NEW RIB FLANGE PER SRM 51-00-01.