What was found
LEVEL 2 EXFOLIATING CORROSION, STATION 640 RBL 12-64, UPPER SURFACE, FORWARD HORIZONTAL. FLANGE OF FLOOR BEAM, AROUND CLIP NUT HOLES. REMOVED CORROSION TREATED, PRIMED PER SRM 51-10-6, 51-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 EXFOLIATING CORROSION, STATION 640 RBL 12-64, UPPER SURFACE, FORWARD HORIZONTAL. FLANGE OF FLOOR BEAM, AROUND CLIP NUT HOLES. REMOVED CORROSION TREATED, PRIMED PER SRM 51-10-6, 51-10-2. (M)