What was found
RIGHT NR 2 UPPER FLAP CARRIAGE HAS A WEAR MARK APPROXIMATELY .040 INCH TO .050 INCH DEEP IN THE VERY UPPER INBOARD EDGE ADJACENT TO THE BONDING LEAD ATTACHMENT TO THE FLAP. BLENDED WEAR MARK TO A SMOOTH DEPRESSION AS PER AVRO FAX. PERFORMED EDDY CURRENT TO BLENDED AREA AND FOUND TO BE CRACK FREE. REPROTECTED THE DAMAGED AREA W/ALOCROM, PRIMED, TOPCOATED AND REPOSITIONED BONDING.