SDR 96ZZZX3098

Service difficulty report · Temp Sensor · Dorner DO328100

Difficulty date
May 8, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N350AD
Make and model
Dorner DO328100
Aircraft serial
3050
Part
Temp Sensor
Part number
31920002
Condition
Corroded
Location
Nr 2 Battery
Component
Marathon
Stage of operation
AP
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found