SDR 96ZZZX644

Service difficulty report · Schrader Valve · Doug DC982

Difficulty date
December 20, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N959U
Make and model
Doug DC982
Aircraft serial
49704
Part
Schrader Valve
Part number
A00314
Condition
Failed
Location
Nlg Strut
Stage of operation
CL
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

STL - FLT 255 - AFTER TAKEOFF WHEN LANDING GEAR WAS RETRACTED, NOSE LANDING GEAR DID NOT RETRACT. CYCLED LANDING GEAR. FOUND NLG STRUT LOW ON AIR PRESSURE. REPLACED SCHRADER VALVE, MFG PN A00314. SERVICED NLG STRUT. LANDING GEAR OPERATION CHECKED NORMAL. CHECK C-1D - 7-28-95 - MCI.