What was found
DURING FIRST TOUCH AND GO LANDING, WHEN FLAPS LOWERED, ABNORMAL CONTROL RESPONSE NOTED. LT FLAP HAS MORE EXTENSION THAN RT FLAP. ABORTED AND MADE NEW APROACH TO A LANDING. FOUND FLAP CONTROL SYSTEM HAD A BENT PULLEY BRACKET WHERE ROD (ALSO BENT) IS ATTACHED. THE BRACKET BENT UNTIL PULLEY WAS CONTACTED CAUSING FLAP PROBLEM.