What was found
FLT 1150 - PHL-PWM - DURING APPROACH TO PWM, LANDING GEAR HANDLE WAS STUCK AND WOULD NOT MOVE. FLIGHT DIVERTED TO BOS WHERE MAINTENANCE COULD BE PERFORMED. BEFORE LANDING AT BOS, LANDING GEAR WAS EXTENDED USING ALTERNATE GEAR METHOD. FLIGHT LANDING WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED LANDING GEAR TELEFLEX CABLES PER MAINTENANCE MANUAL CHAPTER 32-31-03. GEAR SWING PERFORMED AND OPERATED NORMALLY. REFERENCE USAAF97005