As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM SUPPORT INTERCOSTAL HAS CORROSION BETWEEN FS 294.5-312 LBL 12. REMOVED INTERCOSTAL AND FABRICATED NEW INTERCOSTAL AND 2 INCH T-ANGLES 17 INCH BY 2 INCH BY 1 INCH FROM 7075 T6 .090. FABRICATED STRAP 15.5 INCH BY 2 INCH. INSTALLED IAW SRM 53-10-2.