As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM FS 312 UPPER T-CAP CORRODED LBL 12 - RBL 12. FABRICATED T-ANGLE FLOORBEAM AND SPLICE 'L' ANGLE. 'T' ANGLE 82.5 INCH BY 1 INCH FROM 7075 T6 .090. 'L' ANGLES 14 INCH BY 1 INCH BY 1 INCH 2 FROM 7075 T6 .063 INSTALLED IAW SRM 53-10-9.