What was found
FORWARD CARGO STATION 328 CABIN FLOORBEAM HAS CORROSION RBL 24-56. FABRICATED 'L' ANGLES, TWO 1 INCH BY 2 INCH BY 100 INCH, ONE 1INCH BY 2 INCH BY 30 INCH FROM BAC 1505 100246 T-ANGLE, TWO 1 FOOT 1.5 INCHES BY .063 INCH AND TWO 1 INCH BY 1 INCH BY 8 INCH BY .063 INCH FROM 7075-0 IAW SRM 53-10-9. INSTALLED REPAIRS IAW 51-30-2, 53-10-9, 51-30-2.