What was found
RIGHT OUTBOARD FLAP BADLY CORRODED INBOARD END OF FLAP. CUT OUT CORRODED AREA 4.375 INCH BY 2.625 INCH. FABRICATED FILLER FROM 7075-T8 .083 4.375 INCH BY 2.625. FABRICATED ANGLE FROM 7075 T6 2.75 INCH BY .375 INCH. FABRICATED NEW ATTACH ANGLE FROM 2024 T-325 INCH BY 1.25 INCH BY .75 INCH. INSTALLED REPAIRS IAW EO 97-458.