What was found
DURINC C-CHECK, FOUND VERTICAL STABILIZER RIGHT SIDE FIN STATION 86 HAS CORRODED FASTENER HEADS AND BULGE AT THE SEAM. REMOVED CORRODED SKIN FROM STATION 86 CUT ACCESS HOLE BETWEEN STATION 1179-1271. FABRICATED SKIN REPAIR FROM 2024 T3 .40 IAW SRM 55-30 AND EO 97-604, FABRICATED ACCESS COVER IAW SRM 55-30-3 FIG 4, TREATED AND PRIMED SKIN AND ACCESS COVER IAW SRM 51-10-2 AND MM 51-20-0. INSTALLED SKIN AND ACCESS COVER IAW SRM 51-30-2 AND EO 97-064 REV 1/R AND 81103 DATED 6-30-97.