SDR 97ZZZX5146

Service difficulty report · Fan · Braero HS125700A

Difficulty date
November 6, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N727TA
Make and model
Braero HS125700A
Aircraft serial
NA0202
Part
Fan
Condition
Failed
Location
Lavatory
Stage of operation
IN
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT ON GROUND AT GON, WITH ELECTRIC POWER ON IN AIRCRAFT. BURNING SMELL EMITTED FROM LAVATORY. ELECTRIC POWER REMOVED FROM AIRCRAFT. IDENTIFIED CAUSE OF BURNING SMELL TO BE VENTURI OPERATED FAN. AIRCRAFT OPERATED IAW MEL PROCEDURES. FAN AND VENTURI TUBE PN 132322-2-1, SN 84-1449. TSN: 6,696.9 HOURS. FAN MOTOR PN 207640-10 BURNED AND MELTED. INSTALLED OVERHAULED FAN AND VENTURI TUBE. PERFORMED OPERATIONAL CHECK, GOOD. AIRCRAFT RETURNED TO SERVICE 11-6-97.