What was found
FWD CARGO, BS 700, STR 23 TO 24 RT BELL FRAME DENTED. CUT OUT DAMAGED AREA OF BELL FRAME PER SRM 53-10-7 PAGE 1. ALODINED AND PRIMED PER M/M 51-20-0. INSTALLED BELL FRAME REPAIR PER SRM 51-40-3 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO, BS 700, STR 23 TO 24 RT BELL FRAME DENTED. CUT OUT DAMAGED AREA OF BELL FRAME PER SRM 53-10-7 PAGE 1. ALODINED AND PRIMED PER M/M 51-20-0. INSTALLED BELL FRAME REPAIR PER SRM 51-40-3 FIG 1.