What was found
ASYMMETRY I/B FLAP IND ON DEPARTURE WITH I/B FLAP AT 5 DEG. INSTALLED NEW IND, NO HELP. REINSTALLED ORIG FLAP IND. REMOVED AND REPLACED RT I/B TRANSMITTER REF MM 27-52-2, NO HELP KH 193173 ORIG. REINSTALLED JHS 12168, CHECK WIRING FROM LT AND RT I/B FLAP POS TRANSMITTER TO I/B FLAP POS IND, ALL WIRING CHECK GOOD PER 727 WDM 27-52-01 GH 81251. FOUND GROUND WIRE 014-20 BROKEN AT STUD GD90 REPAIR.