What was found
DURING C-CHECK INSPECTION, DISCOVERED CORROSION ON THE RIGHT BULKHEAD TERMINAL FITTING AT STATION 870. REPAIRED BY BLENDING AWAY THE CORROSION, HFEC NDT INSPECTING, FLAP PEENING BLENDED AREA, ALODINING AND DOUBLE PRIMING BARE ALUMINUM AREAS. REPAIRED IAW EVIAA CENTER, ENGINEERING CHANGE/REPAIR AUTHORIZATION NR N930FT-57-002-EAC. (M)