What was found
LOG PAGE: 24836 - DURING CRUISE, WHEEL WELL FIRE WARNING LIGHT AND BELL CAME ON. COMPLETED AOM PROCEDURES AND INDICATION DID NOT RETURN. THE NGU TROUBLESHOT SYSTEM, INSPECTED LOOPS, WIRING, GROMMETS, AND FASTENERS IN L/R WHEELS. NO DEFECTS NOTED. REMOVED WATER CONTAMINATION FROM L/R WHEEL WELL DISCONNECT C/P. SYSTEM CHECK OK IAW MM 2612-1. LOG PAGE 24840 IN ERW R/R FIRE DETECTOR CONTROL UNIT FOR COMPANY CONVENIENCE. OPS CHECK OK IAW 26/14/11. (X)