SDR 98ZZZX743

Service difficulty report · Relay · Frchld SA227DC

Difficulty date
January 18, 1998
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N847LS
Make and model
Frchld SA227DC
Aircraft serial
DC847B
Part
Relay
Part number
A703EB
Condition
Inoperative
Location
Rt Engine
Part time
15 hours
Stage of operation
CR
Nature of condition
J, H
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DFW/ELD - FLT 1253 - WHILE IN CRUISE AT FL 170, CREW RECEIVED RT GEN FAIL LIGHT. QRH CONSULTED AND GENERATOR SWITCH - OFF - RESET - ON INSTRUCTIONS FOLLOWED. GEN CAME BACK ON-INE. APPROX 3 MINUTES LATER, RT GEN FAIL LIGHT AGAIN ILLUMINATED. QRH WAS FOLLOWED AND GENERATOR CAME ON-LINE. THREE MINUTES LATER, FAIL LIGHT ILLUMINATED AGAIN. CREW TURNED THE RT GENERATOR OFF AND CALLED FLIGHT CONTROL. AIRCRAFT DIVERTED INTO HOT AND LANDED WITH NO FURTHER ABNORMALITIES. MAINTENANCE INSPECTED ACFT AND DETERMINED FAULT TO BE CAUSED BY FAULTY GENERATOR CONTROL RELAY. MAINTENANCE REPLACED RELAY AND STARTER GENERATOR AS A PRECAUTION. ENGINE RUNS AND OPERATIONAL CHECKS SATISFACTORY. ACFT RETURNED TO SERVICE.