What was found
J31 LT MLG, PN B00A702925A, SN BADL-479, WAS SENT IN FOR REPAIR. MAGNETIC PARTICLE NDT INSPECTION OF SLIDE TUBE, PN 101A703013, SN BD48, REVEALED AN INDICATION (CRACK) EXTENDING FROM THE TOP OF THE TUBE THROUGH THE HOLE FOR SOCKET SET SCREW, PN 741M1-4D, AND DOWN THE TUBE FOR AN ADDITIONAL 0.520 INCH. SUBJECT SLIDE TUBE HAS BEEN REJECTED, AND WILL BE REPLACED.