What was found
PILOT INITIATED START CYCLE ON LT ENGINE, ROTATION ACHIEVED, FUEL INTRODUCED, NO IGNITION AND ENG FAILED TO START. MX INVEST REVEALED THERE NO AUDIBLE SNAP FROM IGNITERS. FOUND IGNITERS WET WITH FUEL. A NON-BURST MODE EXCITER BOX INSTALLED AND ACFT DISPATCHED. IGNITERS REMOVED, FND WORN CLOSE TO MAX. SPARE EXCITER BOX REMOVED AND ORIG RE-INSTALLED. IGNITION, BOTH PLUGS FIRED, WOULD NOT FIRE WET. 2 NEW IGNITER PLUGS INSTALLED, CHECKED DRY, THEY FIRED. 3 DROPS OF FUEL APPLIED, IGNITERS WOULD FIRE WET. NON-BURST MODE BOX INSTALLED AND 1 OF OLD IGNITERS ATTACHED AND WET WITH FUEL, IGNITER FIRED. IGNITER PLUGS, 231 HRS SINCE INSTALLED. INSTALLED NEW IGNITER PLUGS ON LT ENG AND RT SIDE LUGS CHANGED.