Service difficulty report · Pump · Israel 1124A

Difficulty date
December 18, 2024
Submitted
December 19, 2024
Operation
Air carrier
Aircraft
N22AV
Make and model
Israel 1124A
Aircraft serial
0304
Aircraft time
10,155 hours, 8,281 cycles
Part
Pump
Part number
65WE010313
Part serial
A3215
Condition
Leaking
Location
Hyd System
Stage of operation
CR
How discovered
C
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LH AND RH HYDRAULIC LOW PRESSURE INDICATORS ILLUMINATED IN CRUISE FLIGHT, MAIN PRESSURE INDICATED ZERO PSI. MAINTENANCE OBSERVED LOW HYDRAULIC FLUID LEVEL CAUSED BY LEAK ON RH MAIN HYDRAULIC PUMP. REPLACED RH MAIN HYDRAULIC PUMP, SERVICED RESERVOIR AND CW OPERATIONAL TESTS AS REQUIRED, NO DEFECTS NOTED.

More about the Israel 1124A