What was found
LH AND RH HYDRAULIC LOW PRESSURE INDICATORS ILLUMINATED IN CRUISE FLIGHT, MAIN PRESSURE INDICATED ZERO PSI. MAINTENANCE OBSERVED LOW HYDRAULIC FLUID LEVEL CAUSED BY LEAK ON RH MAIN HYDRAULIC PUMP. REPLACED RH MAIN HYDRAULIC PUMP, SERVICED RESERVOIR AND CW OPERATIONAL TESTS AS REQUIRED, NO DEFECTS NOTED.