What was found
QTY (2) FLOORBEAM ANGLES AT FS 280.00, LBL 9.00, WL 72.00 ARE CRACKED. QTY (2) FLOORBEAM ANGLES AT FS 280.00, LBL 9.0, WL 72.00 REPLACED IAW SRM 51-42-21- AND 51-42-06. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
QTY (2) FLOORBEAM ANGLES AT FS 280.00, LBL 9.00, WL 72.00 ARE CRACKED. QTY (2) FLOORBEAM ANGLES AT FS 280.00, LBL 9.0, WL 72.00 REPLACED IAW SRM 51-42-21- AND 51-42-06. (K)