FORWARD SERVICE DOOR JAMMED. TWO DENTS FORWARD OF RT FORWARD SERVICE DOOR. DENTS OUT OF LIMITS. COMPLIED WITH REPAIR BRAS EO 601R-53-4835 STEPS 1, 2, 3, 4 AND 5. PERFORMED REPAIR OF SERVICE DOOR STRINGER 16/17 OF FIG 245 AND STRINGER 13/14 FIG 295. (M)