What was found
ATTACHMENT HOLE ENLARGED ON OUTBOARD SIDE OF PANEL 684BB, DAMAGED WHILE REMOVING SCREW HOLE DIA WAS .193 NOW .265. INSTALLED FABRICATED 100 COUNTERSINK FREEZE PLUG IAW BRAS EO NR 601-57-6666. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ATTACHMENT HOLE ENLARGED ON OUTBOARD SIDE OF PANEL 684BB, DAMAGED WHILE REMOVING SCREW HOLE DIA WAS .193 NOW .265. INSTALLED FABRICATED 100 COUNTERSINK FREEZE PLUG IAW BRAS EO NR 601-57-6666. (M)