What was found
LT FS 621.00 FLOOR SUPPORT ANGLE IS CRACKED .5 INCH LONG ON OB RADIUS. (K) [07-17-07] MAINTENANCE CUT AWAY DAMAGED ANGLE AND INSTALLED REPAIR ANGLE IAW BOMBARDIER REO 601R53-61-117 REV C. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT FS 621.00 FLOOR SUPPORT ANGLE IS CRACKED .5 INCH LONG ON OB RADIUS. (K) [07-17-07] MAINTENANCE CUT AWAY DAMAGED ANGLE AND INSTALLED REPAIR ANGLE IAW BOMBARDIER REO 601R53-61-117 REV C. (M)