What was found
DEPARTING BUFFALO, GENERATOR NR 1 DROPPED OFF LINE AT 700 FT PER QRH RESET. GENERATOR 2 DROPPED OFF LINE AT 1200 FT AND RESET PER QRH. BOTH GENERATORS OFF LINE FOR APPROXIMATELY 1 MINUTE. SERVICED GEN/IDG 1 WITH 4-5 PUMPS OF OIL. OPS CHECK GOOD. NO LEAKS NOTED REF MM 12-13-24-610-801. OPS CHECK PER 24-20-00-710-801. ACFT OK FOR SERVICE.