Service difficulty report · Sensor · Cndair CL6002B19

Difficulty date
November 15, 2008
Submitted
December 8, 2008
Operation
Air carrier
Aircraft
N467AW
Make and model
Cndair CL6002B19
Aircraft serial
7900
Aircraft time
11,677 hours, 10,855 cycles
Part
Sensor
Condition
Shorted
Location
Overheat
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RECEIVED LT STAGE DUCT MSG INFLIGHT. MSG STAYED ON AFTER RETARDING THRUST LEVER TO IDLE. C/W GVI OF LT 10TH STAGE DUCTING WITH ENGINE RUNNING. NO LEAKS DETECTED. LT 10TH STAGE WARN MSG OCCURRED AGAIN WITH ENGINES SHUTDOWN. CONFIRMED BAD INDICATION. REF 193317/1 FOR NEW DISCREPANCY. FOUND 10TH STAGE DUCT SENSING ELEMENT A14WK SHORTED TO GROUND. R&R A14WK IAW AMM 36-21-04. REF L/P 193317/3 FOR LOOB A FAULT.