What was found
CORROSION FOUND ON FLOOR STRUCTURE FITTING TO FR FS 319.00, WL 79.00, RBL 45.0 FLOOR STRUCTURE FITTING TO FR FS 319.0, WL 79.00, RBL 45.0. REPLACED IAW SRM 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FLOOR STRUCTURE FITTING TO FR FS 319.00, WL 79.00, RBL 45.0 FLOOR STRUCTURE FITTING TO FR FS 319.0, WL 79.00, RBL 45.0. REPLACED IAW SRM 51-42-21.