What was found
NOSE GEAR FAILED TO RETRACT ON SELECTION. FOUND NLG TO BE UNDER SERVICED WITH NITROGEN. STRUT ON LT SHOWED 3 INCHES OF CHROME. NO EVIDENCE OF LEAKS. SERVICED NLG WITH NITROGEN IAW AMM 12-12-32, LEAK AND OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NOSE GEAR FAILED TO RETRACT ON SELECTION. FOUND NLG TO BE UNDER SERVICED WITH NITROGEN. STRUT ON LT SHOWED 3 INCHES OF CHROME. NO EVIDENCE OF LEAKS. SERVICED NLG WITH NITROGEN IAW AMM 12-12-32, LEAK AND OPS CHECKED GOOD.