What was found
PRECAUTIONARY ENG SHUTDOWN OF LT ENG FOR OIL PRESS INDICATION. PRESS INDICATION 22 PSI UPON ENG SHUTDOWN. ENG SHUTDOWN FOR 15 MIN WITH POSITIVE OIL PRESS. SERVICED ENG OIL LT 16.25 PTS, INSPECTED FOUND LOOSE OIL SUPPLY LINE. TORQUED TO 75 FT LBS IAW AMM 79-11-01, INSPECTED MASTER CHIP DETECTOR, NO PARTICLES FOUND IAW 79-21-09. MOTORED ENG NO LEAKS NOTED. RAN ENGS NO LEAKS NOTED. PERFORMED ENG LT CHIP DETECTOR TASK, NO FAULTS FOUND.