What was found
FIRST OFFICER`S WINDSHIELD HEAT TERMINAL BLOCK COVER SMOKING INFLIGHT, WINDSHIELD HEAT OFF SMOKING STOPPED. INSPECTED & FOUND LWR TERMINAL BLOCK SCREW LOOSE CAUSING MOVEMENT & ARCING. SCREW, TERMINAL & TERMINAL BLOCK SHOW EVIDENCE OF DAMAGE FROM ARCING. FOUND ONE WASHER & SPACER MISSING. INSPECTED FIRST OFFICER`S WINDSHIELD & FOUND NO EVIDENCE OF DELAMINATION OR ARCING DAMAGE IAW AMM 56-11-01. PLACED ON MEL.