What was found
L/H WING I/B LE PANEL UPPER MOUNT LANDING HAS A GOUGE ON ANGLE DWG #600-12031. GOUGE IS NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 57-00-00 REV 38. *************AIRCRAFT REMOVED FROM SERVICE************************ EDGE TRIMMED THE CHAFED AREA DIMENSIONS: 1.1"L X .040"W X .100"D. HFEC INSPECTION PERFORMED AT CUTOUT WITH NO INDICATIONS. VERIFIED MINIMUM 2D EDGE DISTANCE BETWEEN TRIMMED AREA AND ADJACENT FASTENERS. RESTORED PROTECTIVE FINISH. ALL WORK PERFORMED IAW ASAP EA #AWAC-CRJ257-01792 REV IR DATED 2022-01-19. WORK COMPLETED ON AERSALE WO #003526 CARD #50011. N438AW TT: 39,745:56 TC: 39,335.