What was found
L/H ELEVATOR HINGE #2 FITTING GOUGED .550"L X .500"W X .010"D BETWEEN FS 59.02 AND FS 62.02. EVALUATED DAMAGE AND FOUND NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 55-20-00 REV 39. *********AIRCRAFT REMOVED FROM SERVICE*************************** PERFORMED BLEND ON FITTING TO A SMOOTH CONTOUR NOT EXCEEDING DIMENSIONS .550"L X .500"W X .010"D IAW ASAP EA AWAC-CRJ255-01896 REV IR DATED 9/27/22. HFEC INSPECTION PERFORMED AT BLEND AREA WITH NO INDICATIONS IAW NDT MANUAL PART 1 51-20- 06 REV 43. VERIFIED NO MATERIAL LOSS WITHIN 2D OF SURROUNDING PRODUCTION FASTENERS. ROTO-PEENED BLEND AREA IAW CRJ 200 SRM 51-24-11 REV 39. RESTORED PROTECTIVE FINISH AT BLEND AREA IAW CRJ200 SRM 51-21-16. ALL WORK PERFORMED WITHIN ALLOWABLE LIMITS IAW ASAP EA AWAC-CRJ255-01896 REV IR DATED 9/27/22. WORK PERFORMED ON AERSALE WO #003718 CARD #20375 CARD ID#1731227. CRS #4AER685B N460AW TT: 39,075:32 TC: 37,789