What was found
R/H HSTAB HINGE #2 I/B FITTING GOUGED .7"L X .1"W X .020"D & O/B FITTING GOUGED .6"L X .1"W X .011"D AT RBL 55.89 AND I/B PLATE .6"L X .1"W X .010"D & O/B PLATE .6"L X .1"W X .017"D. DAMAGE NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 55-20-00 REV 39. *********AIRCRAFT REMOVED FROM SERVICE*************************** PERFORMED BLENDS ON I/B & O/B FITTINGS & PLATES TO A SMOOTH CONTOUR NOT EXCEEDING PRIOR DIMENSIONS IAW MHIRJ REO 601R-55-11-728 REV (--) DATED 2022-09-28. HFEC INSPECTION PERFORMED AT BLEND AREAS WITH NO INDICATIONS IAW NDT MANUAL PART 1 51-20- 06 REV 43. VERIFIED NO MATERIAL LOSS WITHIN 2D OF SURROUNDING PRODUCTION FASTENERS. ROTO-PEENED BLEND AREAS IAW CRJ 200 SRM 51-24-11 REV 39. RESTORED PROTECTIVE FINISH AT BLEND AREAS IAW CRJ200 SRM 51-21-16. ALL WORK PERFORMED WITHIN ALLOWABLE LIMITS IAW MHIRJ REO 601R-55-11-728 REV (--) DATED 09/28/22. WORK PERFORMED ON AERSALE WO #003718 CARD #20370 CARD ID#1731194. CRS #4AER685B N460AW TT: 39,075:32 TC: 37,789