What was found
DENT ON AFT FUSELAGE SKIN AT FS589-605 AND BETWEEN S22R -25R. ADDITIONAL DAMAGE TO FS574-589 AND S22R TO 25R. FASTENERS INSTALLED FOUND CLOSE TO RADIUS OF STRINGER & WEAR DAMAGE TO STRINGER FLANGE DUE TO DOOR. LATCH WEAR. PERFORMED TEMPORARY REPAIR TO SKIN, FABRICATED DOUBLER & TRIPLER. FABRICATED DOUBLER FILLER. INSTALLED DOUBLER, TRIPLER & DOUBLER FILLER. BLENDED DAMAGE TO STRINGER FLANGE. PERFORMED HFEC WITH NO INDICATIONS. RESTORED PROTECTIVE FINISH. ALL WORK WITHIN LIMITS WERE PERFORMED IAW REO 601R-53-61-7969 REV --.