What was found
CORROSION ON CARGO FLOOR SILL PN601R31132-58 AT FS605.00+5 AND RBL42. ***** AC REMOVED FROM SERVICE ***** REPLACED FLOOR SILL SUPPORT ANGLE WITH A NEW FABRICATED ANGLE 601R AT FS559 AND LBL28.00. RESTORED PROTECTIVE FINISH. ALL WORK WITHIN LIMITS WAS PERFORMED IAW CRJ200 SRM 51-26-00, SRM 51-61-43, SRM 53-00-00, SRM 51-11-00, SRM 51-25-06, SRM 51-12-00 REV 39, SRM51-25-06 REV 39, AND SRM 51-25-16 REV 39. WORK PERFORMED UNDER AERSALE WORK ORDER 003870, CARD NO. 20064, TT: 39,677:48 TC: 38,656.