What was found
TUL - FOUND STRINGER CORRODED IN LOWER CENTER (BLOWN OUT). CUT OUT 11 INCH SECTION OF CORRODED STRINGER, STATION 483 TO 494 AND INSTALLED NEW SECTION WITH NEW SPLICE ON AFT END PER SRM 53-10-3 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STRINGER CORRODED IN LOWER CENTER (BLOWN OUT). CUT OUT 11 INCH SECTION OF CORRODED STRINGER, STATION 483 TO 494 AND INSTALLED NEW SECTION WITH NEW SPLICE ON AFT END PER SRM 53-10-3 FIG 1. (M)